Ernitec EDNS V1000 series – user manual
Analog Camera Select
Dome Protocol
Dome ID
Camera Name
Hidden
Brightness
Contrast
Saturation
Hue
CH01
None
0
CH1
No
0
0
0
0
To configure dome protocol, select a camera first and set the
communications protocol associated with dome camera using
the Direction keys and ENTER.
NOTE: The settings become effective after saving the
changes and exiting from the menu.
4.5.3 RS485 Setup
The DVR controls the domes via RS-485 communication
protocol. The RS-485 parameters in the DVR must be set to the
same parameters set in dome camera.
Users are allowed to change the RS-485 settings of the DVR.
Select <System Setup> in Main menu, then select <RS485
Setup> from the System Setup menu and press ENTER. The
following menu is displayed.
Unit ID
Baud Rate
Bits
Stop
Parity
The ID number must match the ID address set by the dome. The
Unit ID is in the range of 1 to 255. Note that there cannot be any
two devices on the same bus given the same ID address, or a
conflict may occur.
NOTE: The settings become effective after saving the
changes and exiting from the menu.